Important Safety Information

IMPELLA® LEFT-SIDE DEVICES INDICATION & SAFETY INFORMATION

INDICATIONS FOR USE

High-Risk PCI

The Impella 2.5®, Impella CP® and Impella CP® with SmartAssist® Systems are temporary (≤ 6 hours) ventricular support devices indicated for use during high-risk percutaneous coronary interventions (PCI) performed in elective or urgent, hemodynamically stable patients with severe coronary artery disease, when a heart team, including a cardiac surgeon, has determined high-risk PCI is the appropriate therapeutic option. Use of the Impella 2.5, Impella CP, and Impella CP with SmartAssist Systems in these patients may prevent hemodynamic instability, which can result from repeat episodes of reversible myocardial ischemia that occur during planned temporary coronary occlusions and may reduce peri- and post-procedural adverse events.

Cardiogenic Shock

The Impella 2.5®, Impella CP®, Impella CP® with SmartAssist®, Impella 5.0®, Impella 5.5® with SmartAssist® and Impella LD® Catheters, in conjunction with the Automated Impella Controller™ (collectively, "Impella® System Therapy"), are temporary ventricular support devices intended for short term use (≤ 4 days for the Impella 2.5, Impella CP, and the Impella CP with SmartAssist, and ≤ 14 days for the Impella 5.0, Impella 5.5 with SmartAssist and Impella LD) and indicated for the treatment of ongoing cardiogenic shock that occurs immediately (< 48 hours) following acute myocardial infarction or open heart surgery or in the setting of cardiomyopathy, including peripartum cardiomyopathy, or myocarditis as a result of isolated left ventricular failure that is not responsive to optimal medical management and conventional treatment measures (including volume loading and use of pressors and inotropes, with or without IABP). The intent of Impella System Therapy is to reduce ventricular work and to provide the circulatory support necessary to allow heart recovery and early assessment of residual myocardial function.

Emergency Use Authorization

Impella Left Ventricular (LV) Support Systems (Impella 2.5, Impella CP, Impella CP with SmartAssist, Impella 5.0, and Impella 5.5 with SmartAssist) are authorized for emergency use by HCPs in the hospital setting for providing temporary (≤ 4 days for Impella 2.5, Impella CP, and Impella CP with SmartAssist; and ≤ 14 days for Impella 5.0 and Impella 5.5 with SmartAssist) LV unloading and support to treat critical care patients (i.e. patients in the intensive care unit) with confirmed COVID-19 infection who are undergoing ECMO treatment and who develop pulmonary edema while on V-A ECMO support or late cardiac decompensation from myocarditis while on V-V ECMO support. The Impella LV Support Systems have neither been cleared or approved for the authorized indication for use. The Impella LV Support Systems have been authorized for the above emergency use by the FDA under an EUA. The Impella LV Support Systems have been authorized only for the duration of the declaration that circumstances exist justifying the authorization of the emergency use of medical devices under section 564(b)(1) of the Act, 21 U.S.C. § 360bbb-3(b)(1), unless the authorization is terminated or revoked sooner.

Important Risk Information for Impella devices

Contraindications

The Impella 2.5, Impella CP, Impella CP with SmartAssist, Impella 5.0, Impella 5.5 with SmartAssist and Impella LD are contraindicated for use with patients experiencing any of the following conditions: Mural thrombus in the left ventricle; Presence of a mechanical aortic valve or heart constrictive device; Aortic valve stenosis/calcification (equivalent to an orifice area of 0.6cm2 or less); Moderate to severe aortic insufficiency (echocardiographic assessment graded as ≥ +2); Severe peripheral arterial disease precluding placement of the Impella System; Significant right heart failure*; Combined cardiorespiratory failure*; Presence of an Atrial or Ventricular Septal Defect (including post-infarct VSD)*; Left ventricular rupture*; Cardiac tamponade*

* This condition is a contraindication for the cardiogenic shock indication only.

Potential Adverse Events

Acute renal dysfunction, Aortic valve injury, Bleeding, Cardiogenic shock, Cerebral vascular accident/Stroke, Death, Hemolysis, Limb ischemia, Myocardial infarction, Renal failure, Thrombocytopenia and Vascular injury

In addition to the risks above, there are other WARNINGS and PRECAUTIONS associated with Impella devices.

Visit www.abiomed.com/impella and to learn more.

IMPELLA® RIGHT-SIDED DEVICE INDICATION & SAFETY INFORMATION

INDICATIONS FOR USE

The Impella RP® System is indicated for providing temporary right ventricular support for up to 14 days in patients with a body surface area ≥1.5 m2, who develop acute right heart failure or decompensation following left ventricular assist device implantation, myocardial infarction, heart transplant, or open‐heart surgery.

Emergency Use Authorization

The Impella RP System is authorized to be used by healthcare providers (HCP) in the hospital setting for providing temporary right ventricular support for up to 14 days in critical care patients with a body surface area ≥1.5 m2, for the treatment of acute right heart failure or decompensation caused by complications related to Coronavirus Disease 2019 (COVID‐19), including pulmonary embolism (PE). The Impella RP has been authorized only for the duration of the declaration that circumstances exist justifying the authorization of the emergency use of medical devices under section 564(b)(1) of the Act, 21 U.S.C. § 360bbb‐3(b)(1), unless the authorization is terminated or revoked sooner.

Important Risk Information for Impella RP System

Contraindications

The Impella RP System is contraindicated for patients with the following conditions: Disorders of the pulmonary artery wall that would preclude placement or correct positioning of the Impella RP device. Mechanical valves, severe valvular stenosis or valvular regurgitation of the tricuspid or pulmonary valve. Mural thrombus of the right atrium or vena cava. Anatomic conditions precluding insertion of the pump. Presence of a vena cava filter or caval interruption device, unless there is clear access from the femoral vein to the right atrium that is large enough to accommodate a 22 Fr catheter.

Potential Adverse Events

The potential adverse effects (eg, complications) associated with the use of the Impella RP System: Arrhythmia, Atrial fibrillation, Bleeding, Cardiac tamponade, Cardiogenic shock, Death, Device malfunction, Hemolysis, Hepatic failure, Insertion site infection, Perforation, Phlegmasia cerulea dolens (a severe form of deep venous thrombosis), Pulmonary valve insufficiency, Respiratory dysfunction, Sepsis, Thrombocytopenia, Thrombotic vascular (non-central nervous system) complication, Tricuspid valve injury, Vascular injury, Venous thrombosis, Ventricular fibrillation and/or tachycardia.

In addition to the risks above, there are other WARNINGS and PRECAUTIONS associated with Impella RP.

Visit www.abiomed.com/impella/impella-rp to learn more.

IMPELLA CONNECT® INDICATION & SAFETY INFORMATION

INTENDED USE

Impella Connect® transfers a video image of the screen on the Automated Impella Controller™ to an authorized remote user. The transmitted image can be viewed by authorized remote users. The users can include the hospital’s clinicians, Abiomed local support staff, and Clinical Support Center (CSC) team members.

PRECAUTIONS

  • Impella Connect is not intended to provide real-time information for monitoring patient status on the Automated Impella Controller.

  • During use of the Impella Connect, there will be a delay between when an image appears on the controller screen and when it is displayed at a remote viewing location.

  • The Impella Connect is not a source of patient alarms, nor is its use intended as a replacement for monitoring the controller’s alarms.

  • During use of the Impella Connect, receipt of the displayed controller information is not confirmed by the Automated Impella Controller, nor is the delivery of the displayed controller information to the authorized remote users guaranteed.

  • The Impella Connect is not designed for use during transport.

  • Radiated and conducted electromagnetic interference can affect the performance of the Impella Connect, causing a temporary loss of connectivity. To clear interference, either increase the distance between system components and the EMI source or turn off the EMI source. Any electromagnetic interference related to the Impella Connect will have no impact on any of the controller functional specifications.

  • Portable and mobile RF communications equipment can affect medical electrical equipment.

In addition to the risks above, there are other WARNINGS and PRECAUTIONS associated with Impella devices.